风速计显示警报。三位数字的风速WM44 V3有阅读km / h,英里每小时或m / s。选择3的选择之一是可能的在任何时候按“选择”。他们承认2和3线传感器和有一个10 - 20直流电源输出。功能触发警报警报当风速达到或超过设定的值。它包括一个可配置的延迟,防止被风吹来触发的报警。禁用报警时风速低于设定的值。它也有一个可配置的延迟防止报警器被暂时停用时间低强度的风。ALARM1 ALARM2丧失活力的激活。ALARM2被激活时,阅读会眨眼对危险发出警告。 Alarms configuration: Trigger values, polarity, intermittent or continuous alarm, alarm latching (only ALARM2) Alarms outputs: Relays. Contacts “NO” and “NC” (ALARM1), contact “NO” (ALARM2). Dry contact relay contacts. User Default Setting The setting can be saved as “User Default Setting” and can be retrieved when necessary P00 – (3). If no configuration has been saved, the factory configuration can be reset with this process. Register of minimum and maximum wind values WM44 automatically records the “Minimum” and the “Maximum” wind speed value. To access the programming buttons, insert a flat-headed screwdriver into the groove marked as “Open to program” and lever the front cover out. Press “ENTER” to the see the “Minimum” value and press it again to see the ” Maximum” one. After 3 seconds it will automatically display the current wind speed again.